| Humane permanent accommodations after natural disasters |
![]() |
|
It is beyond all bearing, for how long after a natural disaster people have to live in the tents of emergency aid and often for years must endure cold winters an hot summers, before enough solid accommodations can be placed at the disposal. Our low-cost panel house offers a possibility, to find a low-priced and above all rapid remedy. ![]() suitable - at all climate zones, because of excellent thermal insulation (0,39 W/m2K) - at areas with termites, because free from cellulose - at earthquake active zones, because of the self-supporting construction customisable - by alterable room layout - by eligible position of windows and doors - by choice of locality matching colour quick available - by shippable large number of units on short call - by fast erection (also without crane) an economical solution - by a low price (in particular ordering a large number of units) - by a low shipping volume (3 units per 40" container / trailor) - because completely removable and re-useable - by a long durability |
RapidEcon |
(subject to technical modifications) |
| dimensions: |
7,00m x 7,00m = 49m² |
| room layout: |
living room, 2 bedrooms, kitchenette, bathroom |
| external walls: |
self-supporting sandwich panels, 1,00m x 2,60m x 60mm, outside 0,5mm, inside 0,4mm steel sheet, coated on polyester basis, core of PUR hard foam (without FCKW-/HFCKW), u-value = 0,39 W/m2K, steel u-profiles, steel corner profiles. |
| inner walls: |
self-supporting sandwich panels, 1,00m x 2,60m x 60mm, outside 0,5mm, inside 0,4mm steel sheet, coated on polyester basis, core of PUR hard foam (without FCKW-/HFCKW), u-value = 0,39 W/m2K, steel u-profiles. |
| ceilings: |
self-supporting sandwich panels, 1,00m x length x 60mm, outside 0,5mm, inside 0,4mm steel sheet, coated on polyester basis, core of PUR hard foam (without FCKW-/HFCKW), u-value = 0,39 W/m2K, steel profiles. |
| roof: |
ventilated double pitch roof of 10° inclination, roof covering of steel trapezoidal sheets, coated on polyester basis, 0,915m x length x 40mm upon steel construction, ridge cladding of steel trapezoidal sheets, coated on polyester basis. |
| floor: |
not included in delivery! |
| windows: |
PVC windows with insulation glas, 5x 1,000m x 1,185m + 1x 0,775m x 0,485m, side/bottom hung small iron-work. |
| entrance door: |
insulated PVC external door with framing, 1x 0,985m x 2,090m, inwardly opening, small iron-work, handle set, lock. |
| iternal doors: |
timber sandwich door with framing, 3x 0,985m x 2,090m, small iron-work, handle set, lock. |
| documents: |
architectural drawings, erection instructions. |
| erection: |
upon concrete paving slab made at building site. |
optionally: |
- 120mm wall and ceiling panels instead of 60mm - higher windows or doble windows - canopy above entrance door - transport winding up - erecting instruction, erecting training or complete erection |